Validity of Wearable Technology Assessments of Heart Rate and Energy Expenditure Under Exercise Conditions

dc.contributor.authorBarlowe, LeAna
dc.contributor.authorBlack, Caroline
dc.date.accessioned2023-05-09T18:22:50Z
dc.date.available2023-05-09T18:22:50Z
dc.date.issued2023-04-12
dc.description.abstractApple Watches are just one popular form of tracking fitness metrics including heart rate and caloric expenditure. We tested Apple Watches against gold standard technologies for measuring heart and energy expenditure during light steady-state exercise. We recruited 9 subjects (6F; 3M; Age=20±0.78; Height=171±8.53cm; Weight=184±63.21lbs; Percent body fat=29±8.69%; Predicted VO2max= 38±6.73ml/kg/min) who owned Apple Watches with the most current operating software to participate in this study. Each subject completed 3 5-minute bouts of steady-state exercise on a rower, treadmill, and cycle ergometer in a randomized order. Subjects were allowed to select their own pace with instructions to achieve a “fairly light” intensity. Oxygen consumption was measured via open-circuit spirometry and heart rate was monitored via a three-lead electrocardiogram (ECG). Apple Watch estimates of caloric expenditure and average exercise heart rate were compared with values gathered from oxygen consumption and ECG, respectively. Pearson product-moment correlations were used to compare electrocardiogram and caloric expenditure values between Apple Watch and gold standard measures across the 3 exercise conditions. Correlations for caloric expenditure between the two devices were as follows: treadmill=0.88, bike=0.54, rower=0.87. For heart rate, the correlations were the following: treadmill=0.99, bike=0.96, rower=0.85. These data indicate strong correlations between Apple Watch and ECG with lower correlations between Apple Watch and oxygen consumption, particularly in the cycling condition. Apple Watch appears to accurately measure heart rate; however, it appears to overestimate caloric expenditure.en_US
dc.identifier.urihttps://lair.lr.edu/handle/20.500.12862/134
dc.language.isoen_USen_US
dc.subjectWearable Electronic Devicesen_US
dc.subjectOxygen Consumptionen_US
dc.subjectSpirometryen_US
dc.titleValidity of Wearable Technology Assessments of Heart Rate and Energy Expenditure Under Exercise Conditionsen_US
dc.typeThesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Honors Thesis - Final Draft_LeAna Barlowe.pdf
Size:
471.38 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.72 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections